Low-profile intumescent perimeter seal set designed to upgrade existing proprietary fire doors.
Allows for a cost-effective and clean build-up of non-rated steel frames with only 15mm stops, in lieu of the conventional 25mm stops required for fire doors.
Key Features
- Can provide up to 2 hours fire resistance on proprietary fire doors.
- Non compliant fire doors can be salvaged.
- Cost-effective solution.
- Easy retro-fit installation.
- Ideal for fire engineered solutions where extra protection is necessary for life safety.
Consists of 2 x purpose-designed flame retardant PVC top hat sections, encapsulating intumescent material, with aggressive self-adhesive backing tape.
Gap Size: Nominal 2mm to 3mm perimeter gaps.
Sizes
Dimensions: 1 x (38mm x 1.6mm)
1 x (13mm x 1.6mm)
Approvals
Fire tested to AS/1530 Part 4 for up to 2 hours on proprietary fire door assemblies in accordance with AS1905 Part 1